Skip to main content

Calls, notes, and pulses

Köhler et al. (2017) vocabulary, with pictures from our own frogs

Every team has to answer the same question before measuring anything: what is one call, and what is inside it? This page sets out Köhler et al.’s (2017) definitions, a three-question key for applying them, and real calls from our species, including the hard case for Team 3.

We use Köhler’s call-centered scheme (see the Sep 9 deck): a call is the main sound unit, separated from the next one by a long silence. State this in your methods.

TipListen while you look

Every figure of a real call has a player under it. Press play and a red line follows the sound across the oscillogram and spectrogram, or click the figure to jump to that point. The calls are short, so try ¼ or ⅛ speed: the pitch drops two or three octaves and individual pulses become audible as a rattle or a buzz.

Three units, three zoom levels

Three oscillograms (plots of amplitude over time) of a synthetic call series. A, 3.6 s: three calls about 1.3 s apart, with the long silence between two calls marked as the inter-call interval. B, one call of 0.19 s: two notes separated by a short silent gap, the inter-note interval. C, one note of 0.08 s: six pulses, where the amplitude dips between peaks but never drops to silence.

A synthetic call series, zoomed in three times. All figures on this page are drawn from the same kind of data: the oscillogram (amplitude against time) on top, and where shown, the spectrogram (frequency against time) below.

Panel A: the call series

Audio: three calls about 1.3 s apart; each is two quick, buzzy notes.

Call, note, and pulse are nested, and each one only shows up at its own zoom level. If you are looking at 30 seconds of recording, you can see calls but not pulses. If you are looking at 0.1 s, you can see pulses but you can’t tell where one call ends and the next begins.

Unit Köhler et al. (2017) Zoom to see it
Call The main acoustic unit, separated from other calls by silent intervals “typically longer (often several times longer) than the call.” A call can be given on its own. 10–60 s
Note A subunit of a call, “almost always separated by intervals of silence (i.e., 100% amplitude modulation),” with gaps short relative to the notes. A call with no such subunits is a one-note call. 0.5–2 s
Pulse “A single burst of sound energy, not further subdivided,” separated from other pulses by strong amplitude modulation, which “is often less than 100%.” The smallest unit, “typically in the range of 5–50 ms.” 0.05–0.5 s, oscillogram

And three words for what a note looks like inside:

Term Köhler et al. (2017)
Tonal No amplitude modulation: a smooth, continuous sound. Not pulsed.
Pulsed “A series of well-defined energy bursts (pulses).” You can count them.
Pulsatile “Poorly defined energy bursts … fast alternating amplitude modulation without intermittent silence and no clearly countable peaks (if clearly countable, amplitude peaks refer to pulses).”

Amplitude modulation is how much the loudness rises and falls. If the amplitude drops all the way to silence between two bursts, that is 100% modulation. If it drops to half, that is 50%.

The key: three questions, in order

  1. Zoom out (10–60 s). What unit repeats, with silences longer than itself between repeats? That unit is the call. Measure the inter-call interval and the call rate at this level.
  2. Zoom in to one call (under 1 s). Is it split by fully silent gaps into units longer than a pulse? Those are notes. If there are no silent gaps, it is a one-note call (most of our species).
  3. Zoom in again, on the oscillogram. Inside a note, does the amplitude rise and fall in bursts you can count?
    • Yes: the note is pulsed. Count the pulses.
    • It wobbles, but you can’t say where one burst ends: pulsatile.
    • Smooth: tonal.

Two things trip people up:

  • What separates a pulse from a note is its size and where it sits in the hierarchy, not silence. Pulses can have silent gaps between them (E. jamesdixoni below), and pulses can merge with no silence at all. A 30-ms burst inside a call is a pulse whether or not silence follows it.
  • What separates a call from a pulse is isolation, not length. A 20-ms sound with seconds of silence on either side is a call (E. verrucipes below). Köhler restricts “pulse” to bursts within calls or notes.

Five kinds of amplitude structure

Five synthetic 0.2 s signals at 2.6 kHz, each shown as an oscillogram above a spectrogram. Tonal: a smooth block with no amplitude changes. Pulsatile: shallow, irregular ripples with no countable peaks. Pulsed with dips: 8 countable peaks whose dips do not reach silence. Pulsed with gaps: 8 short bursts separated by silence. Two notes: two long blocks split by one silent gap.

Five synthetic 0.2-s sounds at the same frequency (after Köhler et al. 2017, Fig. 8). Only the amplitude envelope differs.

Tonal Pulsatile Pulsed (dips) Pulsed (gaps) Two notes

Audio: Tonal: a steady, pure tone. Pulsatile: the same tone with a rough, uneven flutter. Pulsed (dips): a tone that throbs 8 times. Pulsed (gaps): 8 separate quick beeps. Two notes: two short tones with a gap between them.

Look at the oscillograms (top row): that is where the differences are. In the spectrograms (bottom row), the tonal and pulsatile sounds are nearly the same bar, and the pulsed sound with shallow dips is only faintly striped.

Count pulses on the oscillogram, not the spectrogram

The same 10 pulses at about 2.6 kHz drawn three ways. The oscillogram shows 10 separate peaks. A spectrogram with a 128-sample (3 ms) window shows 10 separate dark bars. A spectrogram with a 1024-sample (23 ms) window smears them into one continuous bar, so the pulses disappear.

The same 10 pulses, drawn three ways.

A spectrogram averages over a time window. With a long window (good frequency resolution), pulses closer together than the window blur into one bar. With a short window they separate, but the frequency band gets fat. The oscillogram has no window. Count pulses on the oscillogram (or its envelope), and use the spectrogram to check that what you are counting is your frog and not something else at another frequency.

Real calls from our species

E. marnockii: pulsed, the easy case

Oscillogram and spectrogram of one E. marnockii call, about 0.25 s long. Twelve pulses, marked with triangles, get steadily louder toward the end of the call. The amplitude drops nearly to zero between pulses. The spectrogram shows the pulses as a row of spots near 2 kHz, with fainter harmonics near 4.5 and 7 kHz.

Audio: one quick chirp: 12 clicks in about a quarter second, getting louder toward the end.

One call, one note, 12 pulses. The amplitude drops nearly to zero between pulses, so counting them is easy. Pulse rate = pulses ÷ call duration, and the duration is the hard part. The call starts with faint pulses and ends with a tail, so its length depends on your boundary rule (next section). From the first faint pulse to where the tail meets the background it lasts 0.26 s, so 12 ÷ 0.26 s ≈ 47 pulses/s.

The same call: where does it start and end?

One E. marnockii call shown as a waveform, an amplitude curve in decibels relative to the peak, and a spectrogram, with two ways of marking where the call starts and ends. Solid blue lines at twice the background level give 258 ms and include a faint build-up of six quiet pulses and a tail after the last pulse. Dashed red lines at a quarter of the peak amplitude give 109 ms and include only the loud pulses.

The E. marnockii call above with two boundary rules. The middle panel is the amplitude envelope in dB, where faint sound is easy to see.

Six of the 12 pulses come before the call gets loud: a faint build-up that the oscillogram shows as small bumps. After the last loud pulse the sound doesn’t stop at once. It tapers off for about 30 ms (a tail: the call dying away, or an echo off the rock). Both rules in the figure are defensible, and they give durations of 258 ms and 109 ms for the same call.

A team picks one and writes it down: for example, “the call starts at the first pulse at least twice the height of the background and ends where the sound falls back below twice the background.” Whatever the rule, count pulses inside the same boundaries you measure duration between. Six pulses in 109 ms (≈ 55 pulses/s) and 12 in 258 ms (≈ 47 pulses/s) are both honest. Twelve pulses in 109 ms isn’t.

E. jamesdixoni: pulsed, with silent gaps

Oscillogram and spectrogram of one E. jamesdixoni call, about 0.5 s long, with 13 pulses marked. The first ten pulses are close together. The last three are longer, about 30 to 40 ms each, separated by silent gaps, and are still part of the same call. The energy sits near 2.5 kHz throughout.

Audio: a fast run of ticks, then three slower, separate beeps; about half a second in all.

One call, 13 pulses. The first nine are separated by deep dips; the last four by real silence. They are still pulses, not notes: they are short (Devitt et al. 2023 measured jamesdixoni pulses at 0.03 s on average), they are part of one call, and the call keeps the same structure from start to finish. The faint bars near 4.5 kHz before the call are another animal.

E. humboldti: pulsatile onset, then tonal

Oscillogram and spectrogram of one E. humboldti call, about 0.4 s long. It opens with two short bursts that are not separated by silence, then a steady tone near 2.5 kHz that fades out slowly, with no amplitude modulation. A fainter harmonic sits near 5 kHz.

Audio: a short stutter, then a clear, steady whistle that fades out over about 0.4 s.

One call, one note. Two short bursts at the start, then a long smooth tone. Devitt et al. (2023) classified this call as pulsatile rather than pulsed: there is no series of pulses to count, just some modulation at the onset.

E. verrucipes: a short call is still a call

Oscillogram and spectrogram of one E. verrucipes call. The call is a single unpulsed note about 20 ms long, with its energy near 2 kHz, sweeping slightly downward. Fainter harmonics near 4 and 6 kHz also sweep down. The next call comes about 7 s later.

Audio: a single sharp tick, about 20 ms long.

About 20 ms long, which is within the size range of a pulse. But the next call comes about 7 s later, so this is the whole call: one unpulsed note that sweeps down in frequency. Calling it a “pulse” would leave you with a call made of nothing.

The hard case: E. nitidus (Team 3)

Oscillogram of 84 s of an E. nitidus recording. Ten tall, narrow spikes, each one call, stand out above a low band of background noise. The calls come about 8 to 10 s apart.

Audio: 84 s of steady background noise with ten short, sharp calls about 8 to 10 s apart.

Start zoomed out. Each spike is one call, several seconds from the next. There is no question about what a call is in this species. The disagreement is about what is inside one spike.

One E. nitidus call, 0.27 s long, shown as an oscillogram, a spectrogram, and an amplitude envelope. Two strong bursts at the start are followed by shallow ripples that never reach silence, with steady energy near 2.7 kHz. The number of pulses depends on how deep a dip must be: 12 peaks if a 10% dip counts, 7 at 50%, and 2 at 80%.

Audio: one call, about a quarter second: two quick bursts, then a slightly wavering tone.

Zoomed in, one call is 0.27 s long: two strong bursts at the start, then a long tone whose amplitude ripples up and down without ever reaching silence. The bars at 3.8 kHz in the spectrogram are an insect, not the frog.

The two papers your team is reading describe this same structure in different words, and both cite Köhler:

  • Devitt et al. (2023) classified the E. nitidus call as pulsatile and reported no pulse counts.
  • Vázquez-Hernández et al. (2024) described it as “a short whistle with an oscillating amplitude modulation that forms pulses” and counted 7–10 pulses per call, defined as the “number of amplitude modulations.”

Neither is wrong. Köhler’s line between pulsed and pulsatile is whether the peaks are “clearly countable,” and that depends on how deep a dip has to be before you count it. The bottom panel shows the same call counted three ways: 12 peaks if a 10% dip counts, 7 if the amplitude must fall by half, 2 if it must fall by 80%. A 50% rule lands at the bottom of Vázquez-Hernández et al.’s range.

What your team does:

  1. Choose a counting rule and write it down, for example: “a pulse is an envelope peak with a dip of at least 50% of its amplitude between it and each neighbouring peak.” Put this sentence in your methods.
  2. Apply the same rule to every call from every male. A rule applied to some calls and eyeballed for others is worse than no count.
  3. Describe the call honestly. For example: “The call is a single note with incomplete amplitude modulation (pulsatile sensu Devitt et al. 2023); counting envelope peaks with ≥ 50% modulation gives N pulses per call.” That sentence can be compared with both papers.
  4. Compare like with like. Before you set your counts beside Vázquez-Hernández et al.’s, check that your rule gives numbers in their range on a few calls. If it doesn’t, say so rather than forcing it.

Common mix-ups

  • Calling each pulse a “call.” You are zoomed in too far. Zoom out until you can see the silences between calls.
  • Calling a whole short call a “pulse.” Check what’s on either side. If it’s seconds of silence, it’s a call.
  • Calling silent-gap pulses “notes.” Silence alone doesn’t make a note (see E. jamesdixoni).
  • Counting pulses on the spectrogram. The window smears them. Use the oscillogram.
  • Counting the neighbours. Other males show up as fainter calls at the same frequency, and insects as regular ticks at a different frequency. Measure only the focal male.
  • Counting a click. A thin vertical line through every frequency in the spectrogram is a click or a bump on the microphone, not a pulse.
  • Not saying where the call ends. Faint build-up pulses and tails can double or halve a duration (see the E. marnockii example). Your rule has to name both ends.
  • Not saying which scheme you used. Write “call-centered (Köhler et al. 2017)” in your methods, plus your pulse-counting rule if your species is pulsed or pulsatile.

Looking at the envelope in R

To see what you are counting, cut one call out and plot its amplitude envelope with seewave:

library(tuneR)
library(seewave)

wav   <- readWave("my-recording.wav")
piece <- cutw(wav, from = 26.56, to = 26.88, output = "Wave")  # one call
env(piece, envt = "hil", msmooth = c(176, 50))  # ~4 ms smoothing at 44.1 kHz

Count the peaks by eye against your written rule. A pulse count is a temporal measure, so it is safe to take from mp3 recordings (two of the examples above are mp3). The modulation depth is an amplitude measure: use it as your counting rule, but don’t report depth values as results from mp3 material.

Sources

Recordings by T. J. Devitt. Figures and audio clips are made by scripts/make-call-anatomy-figs.R (the start-and-end figure by scripts/make-tail-echo-fig.R); real recordings are band-passed to 1–8 kHz (for display and playback), with spectrogram windows of 256 samples unless labelled.

Prepared with Claude Code (Claude Opus 5.5, Anthropic): figure and audio script, player, the start-and-end figure, a first draft of the text, and figure alt text and audio descriptions.